Captrol 500

Overview

Captrol 500

Process engineers, plant safety workers, and operators need a dependable, low-maintenance level switch for liquids, powders, or bulk solids. For them, the Captrol 500 provides microcontroller-based RF capacitance switching with one-touch calibration, fail-safe operation, and universal power compatibility.

Unlike competitive point level switches that require tools or manual trim-pot calibration, the Captrol 500 features Auto-Cal one-button setup, built-in self-diagnostics, and a driven-guard probe design that eliminates false trips due to coating or buildup—making it one of the most reliable and easiest-to-use level switches available.

Omnitrols 610/710

Features

Ground-Level Calibration

One-Touch Auto-Cal Calibration

No tools or meters needed—just press to calibrate. Reduces setup time by up to 80%.

Non-Contact Technology

Microcontroller-Based RF Capacitance

Provides accurate, drift-free switching with superior noise immunity and long-term stability.

Driven Guard Probe Design

Prevents false trips due to coating, condensation, or conductive buildup on the probe.

Ultra-Low Power

Universal Power Input (115/230 VAC or 24 VDC)

Works across global facilities—reduces spare parts and simplifies installation.

Fail-Safe Mode (High or Low)

Field-selectable configuration ensures a predictable, safe relay state during power loss or fault.

High Sensitivity

Adjustable Sensitivity and Time Delay

Customizable for challenging materials like foams, slurries, and low-dielectric powders.

Graphite Displacer Reliability

Explosion-Proof Construction (NEMA 4, 5, 7, 8, 12)

Certified for hazardous locations and engineered for chemical, petrochemical, and food applications.

Dual LED Status Indicators

Green for probe activity, red for relay energized—offering instant visual confirmation of operation and fault conditions.

Details

Applications

Technical Specifications

Parameter Specification
Technology
Microcontroller-based RF capacitance point level switch
Mounting Options
Integral or remote (up to 50 ft cable)
Power Supply
115 VAC (95–135 V), 230 VAC (180–270 V), or 24 VDC (18–28 V)
Power Consumption
< 3 VA
Output
SPDT or DPDT relay, 5 A @115/230 VAC or 3 A @26 VDC (non-inductive)
Frequency
50–60 Hz
Sensitivity Range
Adjustable from 0.5 pF to 10 pF
Response Time
Adjustable 0.1–30 seconds
Fail-Safe Mode
Field-selectable for High or Low level
Temperature Limits (Electronics)
–40 °F to +160 °F (–40 °C to +71 °C)
Temperature Limits (Probes)
–40 °F to +450 °F (–40 °C to +232 °C), depending on model
Pressure Limits
Standard probes up to 500 psi (3.4 MPa); Teflon® probes up to 400 psi (2.8 MPa)
Indicators
Green LED: probe capacitance above setpoint; Red LED: relay energized
Housing
Cast aluminum, explosion-proof, NEMA 4, 5, 7, 8, 12
Hazardous Area Ratings
NEC Class I, Groups C & D; Class II, Groups E, F, G
Probe Styles
GIMF (Fortron®), GIMN (Noryl®), GT/GTH (Teflon®), GC (Ceramic), GFC (Flexible cable), GAR (Abrasion-resistant SS)
Accessories
Sensitivity sleeves, flange adapters, 90° bends, lagging extensions
Calibration
One-touch Auto-Cal pushbutton—no tools required

Documents and Downloads

Product Flyer

Have a look at the flyer to get all the tech specs and product features. Brochure

User Manual

Read the manual for detailed information and instructions. Manual

Calibrations

Check out a sample cert from our calibration lab. Certificate

Contact Support

If you have a question that we have not covered then just get in touch and we’ll be happy to help.

FAQs

We have tried to answer the most common questions we are asked here.

It uses a microcontroller-based RF capacitance design with one-touch Auto-Cal calibration, eliminating manual tuning and ensuring drift-free, maintenance-free performance.

The Auto-Cal feature drastically simplifies setup by automatically setting the correct trip point for the current material conditions. Technicians only need to press a button to calibrate the switch—eliminating the tedious, error-prone process of manually adjusting multiple trim pots with meters and tools.

Yes. The driven guard probe design prevents false trips caused by buildup or conductive coating, even in viscous or adhesive media.

Absolutely. The Captrol 500 is explosion-proof and rated for Class I & II hazardous locations (NEC Groups C, D, E, F, G).

Just press the Auto-Cal button—no tools or meters required. Calibration takes seconds and is automatically stored by the microcontroller.

The switch accepts 115/230 VAC or 24 VDC power, simplifying plant standardization and inventory.

Choose from a wide range of Teflon®, ceramic, stainless steel, Noryl®, or flexible cable probes for any process or temperature condition.

Yes. The switch’s fail-safe mode can be field-selected for either high-level or low-level operation.

In capacitance switches, conductive buildup (like sticky liquids) on the probe can look like the actual product, causing false alarms. The driven guard is an insulated sleeve around the probe’s center rod that electronically shields the sensing element from this buildup, ensuring only the true presence of bulk product triggers the switch.