764/766/768 (W) Actuator Welded Chamber

Overview

764/766/768 (W)

For refinery and chemical plant engineers, terminal operations teams, maintenance supervisors, and EPC designers who need two independent mechanical level trips in demanding, pressurized applications — without adding vessel penetrations or gasketed joints — the Omnitrol 764W / 766W / 768W delivers dual-actuator displacer switching inside a welded bypass chamber.

Unlike flanged solutions that introduce additional leak paths, the welded W-series provides:

This makes it ideal for pump start/stop, high-high / low-low protection, and mission-critical shutdown applications where mechanical certainty, safety, and long-term reliability matter most.

Actuator Welded Chamber Mounted Switch

Features

Durability

Dual Independent Actuators

Two mechanically separate switching points — perfect for HI/HI-HI alarms or pump start/stop logic.

Welded Chamber Construction

Fewer leak paths and no gasketed joints — superior integrity in pressurized service.

Factory SG Calibration

Ships tuned for your fluid’s specific gravity for accurate, nuisance-free switching.

High-Pressure / High-Temperature Performance

Rated up to 1000 psig @ 500 °F for refinery and chemical service.

Hydrostatic Test Certification

Every unit pressure-tested at 1.5× maximum design pressure.

Material Flexibility

Carbon steel, 304 or 316 stainless steel chamber options; graphite or optional SS displacer.

Hazardous-Area Ready

UL & CSA Approvals

Built for hazardous industrial environments.

Details

The 764W / 766W / 768W welded chamber series is engineered for applications where:

Typical Duties Include:

Standard spacing provides ~4″ differential (adjustable approx. 2–4″), allowing measured response to process surge and preventing short-cycling.

Applications

Technical Specifications

Parameter Specification
Series
764W / 766W / 768W (dual-actuator, welded chamber)
Chamber Diameter
764W: 4″, 766W: 6″, 768W: 8″
Actuation
Two independent mechanical switch points
Switching Gap
~4″ standard, adjustable approx. 2–4″
Specific Gravity
Max SG 1.4; factory-calibrated
Pressure Ratings Available
150–1000 psig @ 500 °F
Chamber Materials
Carbon steel, 304 SS, 316 SS
Displacer
Graphite (standard) or optional stainless steel
Process Connections
1″ NPT standard; other options available
Verification
Hydrostatic test to 1.5× design pressure
Electrical
SPDT / DPDT switch options
Certifications
UL & CSA approved
Use Cases
Pump control, HI/HI-HI alarms, safety shutdowns
Limit Note
Not intended for interface measurement applications

Documents and Downloads

Product Flyer

Have a look at the flyer to get all the tech specs and product features. Brochure

User Manual

Read the manual for detailed information and instructions. Manual

Calibrations

Check out a sample cert from our calibration lab. Certificate

Contact Support

If you have a question that we have not covered then just get in touch and we’ll be happy to help.

FAQs

We have tried to answer the most common questions we are asked here.

No — they ship factory-set to your specific gravity.

The actuator spacing defines the switching differential (the distance between the START and STOP points for a pump). Adjusting this spacing allows engineers to tailor the control logic to the vessel’s dynamics, preventing the pump from running on and off too quickly (short-cycling) and extending pump life.

One instrument — one chamber — two independent setpoints. No additional vessel penetration required.

High-pressure, hot, corrosive, and hazardous service including refineries, chemical plants, terminal operations, and utilities.

Yes — this is a primary use case, with adjustable differential to prevent pump short-cycling.