Skip to content
Corporate
About
Our Brands
Sonitus Systems
L&J Technologies
Shand & Jurs
S&J Biogas
Varec
Partners
Sustainability
News
Case Studies
Careers
Contact
Demo and Trials
Office Locations
Rep Locator
Corporate
About
Our Brands
Sonitus Systems
L&J Technologies
Shand & Jurs
S&J Biogas
Varec
Partners
Sustainability
News
Case Studies
Careers
Contact
Demo and Trials
Office Locations
Rep Locator
Products
Close Products
Open Products
Measurement & Instrumentation
Valves, Flow, Safety & Protection Hardware
Data Transmitters, Displays, Controls & Automation
Software & Digital Solutions
Environmental & Emissions Sensors
Components, Consumables, & Accessories
Products
Level
Servo Level Gauges
Float and Tape, Mechanical, & Automatic Tank Gauges
Float and Tape Transmitters
Radar Level Gauges
Magnetostrictive Level Gauges
Capacitance Level Gauges and Switches
Magnetostrictive Switches
Ultrasonic Switches
Microwave Switches
Top Mounted Level Switches
Chamber Mounted Level Switches
Level Alarms
Temperature
Temperature Probes and Sensors
Sound
Outdoor Sound Monitoring
Indoor Sound Monitoring
Dust and Air Quality
Dust Monitoring
Combination Environmental Monitoring
Combination Air Quality and Noise Monitoring
Vibration
Vibration Monitoring
Vents
Pressure Vents
Vacuum Vents
Pressure and Vacuum Combination Vents
Free Vents
FRP Vents & Hatches
Emergency Vents
Manhole Covers
Hatches
Gauge Hatches
Arrestors
Flame, Deflagration, and Detonation Arrestors
Valves
Valves
Pilot Operated Valves
Blanketing and Recovery
Tank Blanketing and Vapor Recovery
Displays
Ground Level Displays
Touch Panels
Calibration Tools
Remote Calibration
Transmitters
Transmitters
Interfaces, Terminals, and Communications
Wireless Integration
Remote Terminal Units, Field Interfaces, DAQs, and Protocol Converters
Software
Software
Liquid and Inventory Management
Liquids Management Software
Environmental Monitoring
Environmental Software
Wastewater and Biogas
Digester, Burners, Stream Handling
Environmental Monitoring
General Sonitus
Mounting, Protection, & Retrofit Hardware
Retrofit Covers and Stilling Well Adapters
Joints and Jackets
Electronics Upgrade Kits
Electronics Upgrades
Sensor & System Consumables
Sonitus Consumables
BRANDS
Software
Close Software
Open Software
Environmental Intelligence
Conservation Vent Sizing
Inventory Management
SOFTWARE
Automated Environmental Compliance Platform
Monitoring Instrumentation Fleet Management
Community Engagement Platform
Automated Environmental Compliance Platform
Monitoring Instrumentation Fleet Management
Community Engagement Platform
Winsize
Winsize
Wingauge inventory management
Wingauge inventory management
BRANDS
Solutions
Close Solutions
Open Solutions
Storage Tank and Liquid Level Monitoring Solutions
Water Testing and Wastewater Gas Solutions
Environmental Monitoring Solutions
Tank Safety Solutions
SOLUTIONS
Crude Oil Solutions
Chemical Storage Solutions
Fuel Storage Solutions
Calibration, Display, and Interface Solutions
Inventory Control Solutions
Dry Goods Solutions
Crude Oil Solutions
Chemical Storage Solutions
Fuel Storage Solutions
Calibration, Display, and Interface Solutions
Inventory Control Solutions
Dry Goods Solutions
Digester Gas Storage, Transport, and Flaring
Crude Oil Solutions
Digester Gas Storage, Transport, and Flaring
Crude Oil Solutions
Air Quality
Vibration
Boundary Solutions
Power Solutions
Noise
Remote Monitoring
Air Quality
Vibration
Boundary Solutions
Power Solutions
Noise
Remote Monitoring
Flame Propagation Solutions
Pressure Relief and Venting Solutions
Overfill Protection
Flame Propagation Solutions
Pressure Relief and Venting Solutions
Overfill Protection
BRANDS
Services
Close Services
Open Services
Onsite/Field Services
Waste Water Services
Repair & Maintenance
Calibration
Support
Rental Equipment
Industries
Close Industries
Open Industries
Oil & Gas
Waste Water Services
Marine & Ports
Construction & Infrastructure
Chemical & Petrochemical
Food & Beverage
Energy & Utilities
Transportation & Logistics
Pulp & Paper
Manufacturing
Environmental Consulting
Metals & Steel
Engineering & Nuclear
Scientific & Technical Consulting
Pharmaceuticals
Mining & Minerals
Defense
Resources
Close Resources
Open Resources
Downloads & Datasheets
FAQs
Events and Training
Product Certifications
Glossary
Product Configurations Tools
Product Selection Guide
Insights
Get a Quote
End of Line Flame Arresters
WinSize Product Application Sheet
End of Line Flame Arresters
"
*
" indicates required fields
Name
*
Company
*
Phone Number
*
Email
*
Country / State
*
City
*
Address
*
Zip Code
*
What is the Shand & Jurs model number?
*
94306 Vertical End Of Line Flame Arrester
94307 Horizontal End Of Line Flame Arrester
94308 Miniature Flame Arrester
94309 Flame Arrester (Plate Element)
View Data Sheet (94306 Vertical End Of Line Flame Arrester)
View Data Sheet (94307 Horizontal End Of Line Flame Arrester)
View Data Sheet (94308 Miniature Flame Arrester)
View Data Sheet (94309 Flame Arrester (Plate Element))
What is the flange size?
*
The diameter and rating of the connection point where the arrester attaches to the piping system.
2″
4″
6″
8″
10″
12″
How to determine?
Refer to the piping and instrumentation diagrams (P&IDs) or the vent line's physical specifications.
Materials of Construction (Body & Flame Bank)
*
Material specification for the valve body, such as carbon steel, stainless steel, or alloy.
Cast Iron
Cast Steel
Cast Aluminum
304 SS
316 SS
How to determine?
Match with stored product requirements; check tank material specs and process compatibility.
1 - What is the normal operating flow?
*
The typical gas/vapor flow rate under normal tank or process conditions.
SCFH
Cubic Meters per hour
Liters per minute
How to determine?
Check process flow records, flowmeter readings, or process design specifications.
2 - What is the maximum flow rate?
*
The highest possible gas/vapor flow rate during peak or emergency scenarios.
SCFH
Cubic Meters per hour
Liters per minute
How to determine?
Review emergency venting scenarios, process hazard analysis (PHA) documents, or consult with process engineers.
3- What is the operating pressure?
*
The pressure range within the line/system during normal operation.
Inches of Water
PSIG
Ounces Per Square Inch
Pascals
Kilopascals
Millibars
How to determine?
Refer to pressure gauge readings, process data, or design specifications for the system.
4 - What is the maximum allowable pressure drop?
*
The maximum pressure loss across the arrester that the system can tolerate.
Inches of Water
PSIG
Ounces Per Square Inch
Pascals
Kilopascals
Millibars
How to determine?
Consult with process engineers or review process design documents for system limitations.
5 - What is the operating temperature?
*
The normal temperature of the vapor/gas stream where the arrester is installed.
° F
° C
How to determine?
Check temperature instrumentation readings or process design specifications.
6 - What is the gas/vapor composition?
*
The chemical makeup of the vapors passing through the arrester, critical for safety design.
How to determine?
Refer to the product's Safety Data Sheet (SDS) or a laboratory analysis.
7 - What is the distance from the flame/ignition source?
*
The physical distance between the arrester and the nearest potential flame/ignition source.
Feet
Meters
How to determine?
Measure the physical distance on-site or refer to engineering drawings and plant layouts.
8 - What is the mounting configuration?
*
The orientation and installation details of the arrester, such as vertical or horizontal mounting.
How to determine?
Check engineering drawings, piping layouts, or site installation plans.
9 - If horizontal configuration, straight pipe; specify drain plugs.
*
Indicates if drain plugs are required when the arrester is installed horizontally.
How to determine?
Consult with the design engineer or refer to manufacturer guidelines for horizontal installations.
10 - If horizontal configuration, straight pipe; list # of pipe bends.
*
The number of bends in the horizontal pipe run leading to the arrester.
How to determine?
Count the number of bends from the nearest pipe section to the arrester on the engineering drawing.
Current Date
*