Skip to content
Corporate
About
Our Brands
Sonitus Systems
L&J Technologies
Shand & Jurs
S&J Biogas
Varec
Partners
Sustainability
News
Case Studies
Careers
Contact
Demo and Trials
Office Locations
Rep Locator
Corporate
About
Our Brands
Sonitus Systems
L&J Technologies
Shand & Jurs
S&J Biogas
Varec
Partners
Sustainability
News
Case Studies
Careers
Contact
Demo and Trials
Office Locations
Rep Locator
Products
Close Products
Open Products
Measurement & Instrumentation
Valves, Flow, Safety & Protection Hardware
Data Transmitters, Displays, Controls & Automation
Software & Digital Solutions
Environmental & Emissions Sensors
Components, Consumables, & Accessories
Products
Level
Servo Level Gauges
Float and Tape, Mechanical, & Automatic Tank Gauges
Float and Tape Transmitters
Radar Level Gauges
Magnetostrictive Level Gauges
Capacitance Level Gauges and Switches
Magnetostrictive Switches
Ultrasonic Switches
Microwave Switches
Top Mounted Level Switches
Chamber Mounted Level Switches
Level Alarms
Temperature
Temperature Probes and Sensors
Sound
Outdoor Sound Monitoring
Indoor Sound Monitoring
Dust and Air Quality
Dust Monitoring
Combination Environmental Monitoring
Combination Air Quality and Noise Monitoring
Vibration
Vibration Monitoring
Vents
Pressure Vents
Vacuum Vents
Pressure and Vacuum Combination Vents
Free Vents
FRP Vents & Hatches
Emergency Vents
Manhole Covers
Hatches
Gauge Hatches
Arrestors
Flame, Deflagration, and Detonation Arrestors
Valves
Valves
Pilot Operated Valves
Blanketing and Recovery
Tank Blanketing and Vapor Recovery
Displays
Ground Level Displays
Touch Panels
Calibration Tools
Remote Calibration
Transmitters
Transmitters
Interfaces, Terminals, and Communications
Wireless Integration
Remote Terminal Units, Field Interfaces, DAQs, and Protocol Converters
Software
Software
Liquid and Inventory Management
Liquids Management Software
Environmental Monitoring
Environmental Software
Wastewater and Biogas
Digester, Burners, Stream Handling
Environmental Monitoring
General Sonitus
Mounting, Protection, & Retrofit Hardware
Retrofit Covers and Stilling Well Adapters
Joints and Jackets
Electronics Upgrade Kits
Electronics Upgrades
Sensor & System Consumables
Sonitus Consumables
BRANDS
Software
Close Software
Open Software
Environmental Intelligence
Conservation Vent Sizing
Inventory Management
SOFTWARE
Automated Environmental Compliance Platform
Monitoring Instrumentation Fleet Management
Community Engagement Platform
Automated Environmental Compliance Platform
Monitoring Instrumentation Fleet Management
Community Engagement Platform
Winsize
Winsize
Wingauge inventory management
Wingauge inventory management
BRANDS
Solutions
Close Solutions
Open Solutions
Storage Tank and Liquid Level Monitoring Solutions
Water Testing and Wastewater Gas Solutions
Environmental Monitoring Solutions
Tank Safety Solutions
SOLUTIONS
Crude Oil Solutions
Chemical Storage Solutions
Fuel Storage Solutions
Calibration, Display, and Interface Solutions
Inventory Control Solutions
Dry Goods Solutions
Crude Oil Solutions
Chemical Storage Solutions
Fuel Storage Solutions
Calibration, Display, and Interface Solutions
Inventory Control Solutions
Dry Goods Solutions
Digester Gas Storage, Transport, and Flaring
Crude Oil Solutions
Digester Gas Storage, Transport, and Flaring
Crude Oil Solutions
Air Quality
Vibration
Boundary Solutions
Power Solutions
Noise
Remote Monitoring
Air Quality
Vibration
Boundary Solutions
Power Solutions
Noise
Remote Monitoring
Flame Propagation Solutions
Pressure Relief and Venting Solutions
Overfill Protection
Flame Propagation Solutions
Pressure Relief and Venting Solutions
Overfill Protection
BRANDS
Services
Close Services
Open Services
Onsite/Field Services
Waste Water Services
Repair & Maintenance
Calibration
Support
Rental Equipment
Industries
Close Industries
Open Industries
Oil & Gas
Waste Water Services
Marine & Ports
Construction & Infrastructure
Chemical & Petrochemical
Food & Beverage
Energy & Utilities
Transportation & Logistics
Pulp & Paper
Manufacturing
Environmental Consulting
Metals & Steel
Engineering & Nuclear
Scientific & Technical Consulting
Pharmaceuticals
Mining & Minerals
Defense
Resources
Close Resources
Open Resources
Downloads & Datasheets
FAQs
Events and Training
Product Certifications
Glossary
Product Configurations Tools
Product Selection Guide
Insights
Get a Quote
Emergency Vent - API 7TH Edition
WinSize Product Application Sheet
Emergency Vent - API 7TH Edition
"
*
" indicates required fields
Name
*
Company
*
Phone Number
*
Email
*
Country / State
*
City
*
Address
*
Zip Code
*
What is the Shand & Jurs model number?
*
Identifies the specific emergency vent model being used.
94065 FRP Emergency Vent & Manhole Cover
94200 Emergency Relief Vent/Manhole Cover
94201 Emergency Relief Vent/Manhole Cover with Expanda-Seal
94210 Emergency Relief Vent/Hinged Style
94221 Emergency Vent & Manhole Cover
94225 Emergency Vent & Manhole Cover (Spring Loaded Vacuum)
94510 Magna Vent, Magnetically Sealed
94580 Combo Flame Arrester and Magna Emergency Vent
How to determine?
Refer to equipment datasheet, purchase order, or nameplate on the vent or product selection guide and configurator tool.
View Data Sheet (94065 FRP Emergency Vent & Manhole Cover)
View Data Sheet (94200 Emergency Relief Vent/Manhole Cover)
View Data Sheet (94201 Emergency Relief Vent/Manhole Cover with Expanda-Seal)
View Data Sheet (94210 Emergency Relief Vent/Hinged Style)
View Data Sheet (94221 Emergency Vent & Manhole Cover)
View Data Sheet (94225 Emergency Vent & Manhole Cover (Spring Loaded Vacuum)
View Data Sheet (94510 Magna Vent, Magnetically Sealed)
View Data Sheet (94580 Combo Flame Arrester and Magna Emergency Vent)
What are the materials of construction?
*
The material(s) used for the vent body, seat, and other wetted components.
316SS
304SS
Aluminum
Cast Iron
Cast Steel
Ductile Iron
How to determine?
Check datasheet, material specifications, or product catalog.
1 - What type of tank do you have?
*
Identifies whether the tank is fixed roof, floating roof, cone roof, etc.
Horizontal
Vertical
Spherical
How to determine?
Refer to engineering drawings, tank datasheet, or site inspection.
Diameter
*
*
Feet
Meters
Height
*
*
Feet
Meters
2 - What is the set pressure?
*
The pressure at which the emergency vent opens to relieve excess pressure.
Inches of Water
PSIG
Ounces Per Square Inch
Pascals
Kilopascals
Millibars
How to determine?
Confirm from design documents or vent specifications.
3 - What is the maximum relieving pressure?
*
The maximum pressure that can be safely relieved through the vent.
Inches of Water
PSIG
Ounces Per Square Inch
Pascals
Kilopascals
Millibars
How to determine?
Refer to API 2000 sizing requirements or engineering design basis.
4 - What is the set vacuum (Only for 94221 and 94225)?
The vacuum condition at which the vent opens to protect the tank from collapse.
Inches of Water
PSIG
Ounces Per Square Inch
Pascals
Kilopascals
Millibars
How to determine?
Check tank design vacuum rating and vent specifications.
5 - Enter credits for normal venting (SCFH)
*
Credit given to normal vent capacity that contributes to total venting requirements.
How to determine?
Use SCFH values from vent datasheet or engineering calculations.
6 - What is the tank operating pressure?
*
The selected operating pressure, which determines the flow calculation per API 2000.
(*Selection of Operating Pressure Determines Flow Calculation*)
1-15 PSI (7-103kPa)
Equal to or Below 1 PSI (7kPa)
How to determine?
Refer to tank operating guidelines or process control documentation.
7 - What is the environmental factor? (Bare Metal = 1)
*
A correction factor accounting for surface conditions, corrosion, or coatings.
How to determine?
Use API 2000 guidance; if unknown, enter 1.
Product Chemical Properties
8 - What is the product?
*
The chemical stored in the tank requiring venting protection.
How to determine?
Refer to process records, product datasheet, or SDS.
9 - What is the latent heat of vaporization?
*
The energy required to vaporize the liquid product.
How to determine?
Refer to product SDS or chemical property tables.
10 - What is the absolute temperature of the relieving vapor (Boiling Point in Degrees Rankine)?
*
Temperature of the vapor at relieving conditions, expressed in degrees Rankine.
How to determine?
Calculate from operating data or use product thermodynamic tables.
11 - What is the relative molecular mass of the vapor?
*
The molecular weight of the vapor, used in vent sizing calculations.
How to determine?
Refer to product SDS or chemical property database.
Current Date
*
MM slash DD slash YYYY